Cable Tray Fittings: Bends, Tees, Crosses, Reducers
Cable Tray Fittings: Bends, Tees, Crosses, Reducers

Cable Tray Fittings: Bends, Tees, Crosses, Reducers

FOB
Shipping:
Express Delivery
Product details
FAQ
Essential details
Shipping:Express Delivery
Product Introduction

Our cable tray fittings let a cable tray run change direction, change level, branch, or change width, so that a complete route can be built from straight lengths and fittings. The range covers horizontal and vertical bends, tees, crosses, reducers, and offset bends, for trough-type (solid-bottom), tray-type (perforated), and ladder-type tray. Fittings are made in the same material, finish, width, and depth as the straight tray, so the route is uniform from end to end. The diagram below shows the standard fitting shapes, and custom angles and sizes are made to your drawings.

Request a Quote

Or email admin@wananelectric.com, or call or WhatsApp +86 18823394830.

Key Features

  • Complete range: bends, tees, crosses, reducers, and offset bends for horizontal and vertical changes of route
  • Matches the tray: same material, finish, width, depth, and thickness as the straight tray
  • Three tray types: fittings for trough-type, tray-type (perforated), and ladder-type tray
  • Smooth edges and curves: formed to guide cables without sharp edges that could damage insulation
  • Standard and custom: standard angles and sizes, plus custom angles, radii, and dimensions on request
  • Joint hardware included or available: splice plates, bolts, and nuts that match the fittings
  • Several materials: pre-galvanized steel, hot-dip galvanized steel, stainless steel, aluminum alloy, and other finishes [confirm the materials you supply]

Fitting Types

FittingWhat it doesDiagram codes
Horizontal bendChanges direction of a run in the horizontal planeA3 (trough), A24 (ladder), A25 (tray)
Horizontal teeSplits a run into two branches in the horizontal planeA2 (trough), A26 (ladder), A27 (tray)
Horizontal crossJoins four directions at one pointA17 (trough), A28 (ladder), A29 (tray)
ReducerChanges the width of the tray from one size to anotherA1, A10, A21, A22
Vertical bend (up, down, left, right)Takes the run up or down, turning left or right as it goesA11, A12, A13, A14, A15, A19
Vertical concave and convex bendTakes the run over or under an obstacle, or round a corner in the vertical planeA30 to A33 (ladder and tray)
Vertical teeBranches the run upward, downward, or sideways in the vertical planeA4, A5, A6, A7, A8, A9, A18, A20
Vertical crossJoins runs in several vertical directionsA16, A23
High-low offset bendShifts the run to a different heightA34
Horizontal offset bendShifts the run sideways to a parallel lineA35

Specifications

ItemDetails
Tray typesTrough-type (solid-bottom), tray-type (perforated), ladder-type
Width[confirm range, mm]
Depth (side rail height)[confirm range, mm]
Bend angles[confirm: e.g. 30°, 45°, 60°, 90°]
Bend radius[confirm, mm]
Thickness[confirm, mm, to match the tray]
Material and finish[confirm: pre-galvanized, hot-dip galvanized, stainless steel, aluminum, powder coated]
Joint hardware[confirm: splice plates, bolts, and nuts, included or separate]

Where to Use It

  • Commercial and public buildings, for turns and branches in the main route
  • Industrial plants, power plants, and substations
  • Data centers and telecom rooms
  • Tunnels, airports, and infrastructure projects
  • Any tray run that changes direction, height, or width

Good to Know

  • Match the fitting to the tray: the fitting must have the same type, width, depth, material, and finish as the straight tray it joins
  • Check the bend radius: the radius must not be smaller than the minimum bend radius of the largest cable in the tray
  • Support near the fitting: supports should be placed close to each fitting, following the design and the manufacturer's instructions
  • Bond across joints: splice joints at fittings should be bonded to keep the tray electrically continuous, tested according to your project specification
  • Treat cut edges: if a fitting is cut or adjusted on site, treat the exposed edges as the manufacturer instructs
  • Send a layout: a route drawing helps us count the fittings you need, because the number of bends and tees varies with the layout

Why Choose Wanan

Wanan has been manufacturing cable management products since 2004, with a 20,000 m² factory. We supply EPC contractors, MEP contractors, and distributors, with drawings, OEM/ODM service, and documents such as material certificates and inspection reports on request. Send us your route drawing, tray sizes, and finish, and our team will quote straight tray and fittings together.

Request a Quote

Or email admin@wananelectric.com, or call or WhatsApp +86 18823394830.

Copyright ©️ 2026, Shenzhen Wanan Industrial Co.,Ltd.. All Rights Reserved. Sitemap | Privacy Policy

Follow Us

Whatsapp.jpg

E-mail:

+86 18823394830

Tel:

abby@wananelectric.com

Whatsapp:

+86 18823394830

PRODUCT

Cable Tray

Metal Electrical Conduit

wanan-logo.png240.png

Room 17A01, Block 1, Yintai Building, No. 15 Huilong Road, Shengping Community, Longcheng Street, Longgang District, Shenzhen City,

Guangdong Province, China 

Shenzhen Wanan Industrial Co., Ltd. is a China-based manufacturer of Cable Tray Systems and GI Electrical Conduits, established in 2004.

We manufacture perforated cable trays, cable ladders, cable trunking, galvanized and ZAM cable trays, and EMT, IMC and rigid steel conduits. With 22+ years of manufacturing experience, we provide factory-direct supply, OEM/ODM customization, and technical support for EPC contractors, MEP contractors, distributors, and industrial projects worldwide.

Quick Links